The Design of power saving mechanisms in Ethernet Passive Optical Networks, слайд №1The Design of power saving mechanisms in Ethernet Passive Optical Networks, слайд №2The Design of power saving mechanisms in Ethernet Passive Optical Networks, слайд №3The Design of power saving mechanisms in Ethernet Passive Optical Networks, слайд №4The Design of power saving mechanisms in Ethernet Passive Optical Networks, слайд №5The Design of power saving mechanisms in Ethernet Passive Optical Networks, слайд №6The Design of power saving mechanisms in Ethernet Passive Optical Networks, слайд №7The Design of power saving mechanisms in Ethernet Passive Optical Networks, слайд №8The Design of power saving mechanisms in Ethernet Passive Optical Networks, слайд №9The Design of power saving mechanisms in Ethernet Passive Optical Networks, слайд №10The Design of power saving mechanisms in Ethernet Passive Optical Networks, слайд №11The Design of power saving mechanisms in Ethernet Passive Optical Networks, слайд №12The Design of power saving mechanisms in Ethernet Passive Optical Networks, слайд №13The Design of power saving mechanisms in Ethernet Passive Optical Networks, слайд №14The Design of power saving mechanisms in Ethernet Passive Optical Networks, слайд №15The Design of power saving mechanisms in Ethernet Passive Optical Networks, слайд №16The Design of power saving mechanisms in Ethernet Passive Optical Networks, слайд №17The Design of power saving mechanisms in Ethernet Passive Optical Networks, слайд №18The Design of power saving mechanisms in Ethernet Passive Optical Networks, слайд №19The Design of power saving mechanisms in Ethernet Passive Optical Networks, слайд №20The Design of power saving mechanisms in Ethernet Passive Optical Networks, слайд №21The Design of power saving mechanisms in Ethernet Passive Optical Networks, слайд №22The Design of power saving mechanisms in Ethernet Passive Optical Networks, слайд №23The Design of power saving mechanisms in Ethernet Passive Optical Networks, слайд №24The Design of power saving mechanisms in Ethernet Passive Optical Networks, слайд №25The Design of power saving mechanisms in Ethernet Passive Optical Networks, слайд №26The Design of power saving mechanisms in Ethernet Passive Optical Networks, слайд №27The Design of power saving mechanisms in Ethernet Passive Optical Networks, слайд №28The Design of power saving mechanisms in Ethernet Passive Optical Networks, слайд №29The Design of power saving mechanisms in Ethernet Passive Optical Networks, слайд №30The Design of power saving mechanisms in Ethernet Passive Optical Networks, слайд №31The Design of power saving mechanisms in Ethernet Passive Optical Networks, слайд №32The Design of power saving mechanisms in Ethernet Passive Optical Networks, слайд №33

Вы можете ознакомиться и скачать презентацию на тему The Design of power saving mechanisms in Ethernet Passive Optical Networks. Доклад-сообщение содержит 33 слайдов. Презентации для любого класса можно скачать бесплатно. Если материал и наш сайт презентаций Mypresentation Вам понравились – поделитесь им с друзьями с помощью социальных кнопок и добавьте в закладки в своем браузере.

Слайды и текст этой презентации


Слайд 1





The Design of power saving mechanisms in Ethernet Passive Optical Networks
Yun-Ting Chiang
Advisor: Prof Dr. Ho-Ting Wu
2013.10.28
Описание слайда:
The Design of power saving mechanisms in Ethernet Passive Optical Networks Yun-Ting Chiang Advisor: Prof Dr. Ho-Ting Wu 2013.10.28

Слайд 2





Outline
Introduction
Optical-Fiber Network
Passive Optical Network (PON)
EPON
Interleaved Polling with Adaptive Cycle Time (IPACT)
The Design of Power Saving mechanisms in Ethernet Passive Optical Networks
Two energy-modes in ONU
Add doze mode in ONU
Improve three energy-modes in ONU
Clockwise three energy-modes switching
Counterclockwise three energy-modes switching
Upstream scheduling
Downstream scheduling
Simulation result
Conclusion
Описание слайда:
Outline Introduction Optical-Fiber Network Passive Optical Network (PON) EPON Interleaved Polling with Adaptive Cycle Time (IPACT) The Design of Power Saving mechanisms in Ethernet Passive Optical Networks Two energy-modes in ONU Add doze mode in ONU Improve three energy-modes in ONU Clockwise three energy-modes switching Counterclockwise three energy-modes switching Upstream scheduling Downstream scheduling Simulation result Conclusion

Слайд 3





Passive Optical Network (PON)
Описание слайда:
Passive Optical Network (PON)

Слайд 4





Passive Optical Network (PON)
Optical line terminal (OLT)
Optical network units (ONUs) or 
    Optical network terminals (ONTs)
Use broadcast on Downstream
Use TDMA on Upstream
All ONUs register to OLT with LLID
Описание слайда:
Passive Optical Network (PON) Optical line terminal (OLT) Optical network units (ONUs) or Optical network terminals (ONTs) Use broadcast on Downstream Use TDMA on Upstream All ONUs register to OLT with LLID

Слайд 5





EPON
REPORT and GATE message
REPORT
ONU to report its bandwidth requirements
OLT passes REPORT to the DBA algorithm
GATE
After executing DBA algorithm, OLT transmits GATE down-stream to issue up to four transmission grants to ONU
Transmission start time 
Transmission length 
Timestamp (used by ONU for synchronization)
Описание слайда:
EPON REPORT and GATE message REPORT ONU to report its bandwidth requirements OLT passes REPORT to the DBA algorithm GATE After executing DBA algorithm, OLT transmits GATE down-stream to issue up to four transmission grants to ONU Transmission start time Transmission length Timestamp (used by ONU for synchronization)

Слайд 6





Interleaved Polling with Adaptive Cycle Time (IPACT)
OLT maintain a Table with Byte and RTT
First grant, G(1), is set to some arbitrary value
In polling cycle n, ONU measures its backlog in bytes at end of current upstream data transmission & piggybacks the reported queue size, Q(n), at end of G(n) 
Q(n) used by OLT to determine next grant G(n+1) => adaptive cycle time & dynamic bandwidth allocation
If Q(n)=0, OLT issues zero-byte grant to let ONU report its backlog for next grant
Описание слайда:
Interleaved Polling with Adaptive Cycle Time (IPACT) OLT maintain a Table with Byte and RTT First grant, G(1), is set to some arbitrary value In polling cycle n, ONU measures its backlog in bytes at end of current upstream data transmission & piggybacks the reported queue size, Q(n), at end of G(n) Q(n) used by OLT to determine next grant G(n+1) => adaptive cycle time & dynamic bandwidth allocation If Q(n)=0, OLT issues zero-byte grant to let ONU report its backlog for next grant

Слайд 7


The Design of power saving mechanisms in Ethernet Passive Optical Networks, слайд №7
Описание слайда:

Слайд 8





The Design of Power Saving mechanisms in Ethernet Passive Optical Networks
Two energy-modes in ONU
Add doze mode in ONU
Improve three energy-modes in ONU
Описание слайда:
The Design of Power Saving mechanisms in Ethernet Passive Optical Networks Two energy-modes in ONU Add doze mode in ONU Improve three energy-modes in ONU

Слайд 9





Two energy-modes in ONU
In L. Shi, B. Mukherjee, and S. S. Lee, "Efficient PON with Sleep-Mode ONU: Progress, Challenges, and Solutions," refer two energy-modes including active and sleep modes. They separate high/low priority packet.
Описание слайда:
Two energy-modes in ONU In L. Shi, B. Mukherjee, and S. S. Lee, "Efficient PON with Sleep-Mode ONU: Progress, Challenges, and Solutions," refer two energy-modes including active and sleep modes. They separate high/low priority packet.

Слайд 10





Early wake up
Описание слайда:
Early wake up

Слайд 11





Lei Shi, Biswanath Mukherjee and Sang-Soo Lee’s research
Didn’t consider downstream high priority data delay
Описание слайда:
Lei Shi, Biswanath Mukherjee and Sang-Soo Lee’s research Didn’t consider downstream high priority data delay

Слайд 12





Add doze mode in ONU
Описание слайда:
Add doze mode in ONU

Слайд 13





Add doze mode in ONU
ONU Tx: off   Rx:on
Downstream high priority data won’t trigger sleep ONU wake.
Doze mode can make OLT send downstream data earlier.
Описание слайда:
Add doze mode in ONU ONU Tx: off Rx:on Downstream high priority data won’t trigger sleep ONU wake. Doze mode can make OLT send downstream data earlier.

Слайд 14





Add doze mode in ONU
Описание слайда:
Add doze mode in ONU

Слайд 15





Add doze mode in ONU : Weak point
Doze mode will implement even no downstream data.
Low doze mode utilization
Active mode can’t turn to doze mode when no downstream data.
Описание слайда:
Add doze mode in ONU : Weak point Doze mode will implement even no downstream data. Low doze mode utilization Active mode can’t turn to doze mode when no downstream data.

Слайд 16





Improve three energy-modes in ONU
Clockwise three energy-modes switching
Counterclockwise three energy-modes switching
Описание слайда:
Improve three energy-modes in ONU Clockwise three energy-modes switching Counterclockwise three energy-modes switching

Слайд 17





Clockwise three energy-modes switching
Описание слайда:
Clockwise three energy-modes switching

Слайд 18





Clockwise three energy-modes switching
Consider performance
A -> S
[1] No upstream and downstream data when OLT get ONUx’s REPORT.
A -> D
[2] No upstream data but has downstream data when OLT get ONUx’s REPORT.
S -> A
[3] Upstream high priority data coming
// Early wake up
S -> D
[4] Stay at sleep mode for consecutive Y clock 
// variable Y protects downstream high priority data,Y is maximum of downstream high priority data delay.
Описание слайда:
Clockwise three energy-modes switching Consider performance A -> S [1] No upstream and downstream data when OLT get ONUx’s REPORT. A -> D [2] No upstream data but has downstream data when OLT get ONUx’s REPORT. S -> A [3] Upstream high priority data coming // Early wake up S -> D [4] Stay at sleep mode for consecutive Y clock // variable Y protects downstream high priority data,Y is maximum of downstream high priority data delay.

Слайд 19





Clockwise three energy-modes switching
D -> A
[5] Stay at doze mode for consecutive Z clock || upstream  high priority data coming
// Timer avoids upstream long low priority data delay 
// variable Y、Z protects upstream low priority data , Y + Z is maximum upstream low priority data delay 
p.s.
Active mode trigger:  If report msg. request bandwidth = 0, means no upstream data.
Описание слайда:
Clockwise three energy-modes switching D -> A [5] Stay at doze mode for consecutive Z clock || upstream high priority data coming // Timer avoids upstream long low priority data delay // variable Y、Z protects upstream low priority data , Y + Z is maximum upstream low priority data delay p.s. Active mode trigger: If report msg. request bandwidth = 0, means no upstream data.

Слайд 20





Counterclockwise 
three energy-modes switching
Описание слайда:
Counterclockwise three energy-modes switching

Слайд 21





Counterclockwise 
three energy-modes switching
Consider power saving
A -> S
[1] No upstream and downstream data when OLT get ONUx’s REPORT.
A -> D
[2] No upstream data but has downstream data when OLT get ONUx’s REPORT
S -> A
[3] Stay at sleep mode for Y clock || upstream  high priority data coming
// variable Y protects downstream high priority data,Y is maximum of downstream high priority data delay.
Описание слайда:
Counterclockwise three energy-modes switching Consider power saving A -> S [1] No upstream and downstream data when OLT get ONUx’s REPORT. A -> D [2] No upstream data but has downstream data when OLT get ONUx’s REPORT S -> A [3] Stay at sleep mode for Y clock || upstream high priority data coming // variable Y protects downstream high priority data,Y is maximum of downstream high priority data delay.

Слайд 22





Counterclockwise 
three energy-modes switching
D -> S
[4] Stay at doze mode for consecutive Z ms
// Force
// Timer avoids upstream long low priority data delay 
// variable Y、Z protects upstream low priority data , Y + Z is maximum upstream low priority data delay 
//  Switch from Doze mode to Sleep mode is no delay so downstream high priority data  increase Y clock delay, it’s maximum of downstream high priority data delay
D -> A
[5] upstream high priority  data coming
// early wake up
p.s.
Active mode trigger:  If report msg. request bandwidth = 0, means no upstream data.
Описание слайда:
Counterclockwise three energy-modes switching D -> S [4] Stay at doze mode for consecutive Z ms // Force // Timer avoids upstream long low priority data delay // variable Y、Z protects upstream low priority data , Y + Z is maximum upstream low priority data delay // Switch from Doze mode to Sleep mode is no delay so downstream high priority data increase Y clock delay, it’s maximum of downstream high priority data delay D -> A [5] upstream high priority data coming // early wake up p.s. Active mode trigger: If report msg. request bandwidth = 0, means no upstream data.

Слайд 23





Upstream scheduling
Using Limited service.
Limited service : OLT grants requested number of bytes, but no more than MTW 
OLT polling table increase ONU state.
Описание слайда:
Upstream scheduling Using Limited service. Limited service : OLT grants requested number of bytes, but no more than MTW OLT polling table increase ONU state.

Слайд 24





Downstream scheduling
Although downstream slot and upstream slot are difference but there have some relationship.
Different from general EPON, because ONU[x] in sleep mode, OLT can’t send downstream data. Downstream scheduling need to be considered.
ONUs’ doze mode maybe overlap so OLT need to select one of ONUs to send downstream data.
Описание слайда:
Downstream scheduling Although downstream slot and upstream slot are difference but there have some relationship. Different from general EPON, because ONU[x] in sleep mode, OLT can’t send downstream data. Downstream scheduling need to be considered. ONUs’ doze mode maybe overlap so OLT need to select one of ONUs to send downstream data.

Слайд 25


The Design of power saving mechanisms in Ethernet Passive Optical Networks, слайд №25
Описание слайда:

Слайд 26





Simulation Result
Clockwise three energy-modes switching 
ONU = 16 
ONU queue size 10MByte
EPON Frame size = 64Bytes ~ 1518 Bytes
Channel capacity = 1Gbps 
Max rate = 100 * 1000 * 1000 = 100Mbps
Guard time = 5 * 10-6
Y : After 20ms the state from sleep to doze
Z : After 30ms the state from doze to active
Simulation time 3s
Описание слайда:
Simulation Result Clockwise three energy-modes switching ONU = 16 ONU queue size 10MByte EPON Frame size = 64Bytes ~ 1518 Bytes Channel capacity = 1Gbps Max rate = 100 * 1000 * 1000 = 100Mbps Guard time = 5 * 10-6 Y : After 20ms the state from sleep to doze Z : After 30ms the state from doze to active Simulation time 3s

Слайд 27





Dynamic downstream loading
Upstream load:1  High = 99%  Low = 1%
Описание слайда:
Dynamic downstream loading Upstream load:1 High = 99% Low = 1%

Слайд 28





Dynamic downstream loading
Upstream load:0.01  High = 50% low = 50%
Описание слайда:
Dynamic downstream loading Upstream load:0.01 High = 50% low = 50%

Слайд 29





Dynamic upstream loading
Downstream load = 10 High = 99% low = 1%
Описание слайда:
Dynamic upstream loading Downstream load = 10 High = 99% low = 1%

Слайд 30





Dynamic upstream loading
Downstream load: 0.01 High = 50% low = 50%
Описание слайда:
Dynamic upstream loading Downstream load: 0.01 High = 50% low = 50%

Слайд 31





Conclusion
In this study, power saving mechanisms focus on  reduce high priority downstream data delay in power saving EPON. 
In order to raise up doze mode utilization, we design new three energy-modes switching mechanisms to increase it.
All results discuss between power saving and performance, it’s trade off. Maybe we can improve traffic scheduling or switching mechanism for future.
Описание слайда:
Conclusion In this study, power saving mechanisms focus on reduce high priority downstream data delay in power saving EPON. In order to raise up doze mode utilization, we design new three energy-modes switching mechanisms to increase it. All results discuss between power saving and performance, it’s trade off. Maybe we can improve traffic scheduling or switching mechanism for future.

Слайд 32





Reference
[1] Glen Kramer and Biswanath Mukherjee “IPACT: A Dynamic Protocol for an Ethernet PON (EPON),” IEEE Communications Magazine, February 2002.
[2] Lei Shi, Biswanath Mukherjee and Sang-Soo Lee “Energy-Efficient PON with Sleep-Mode ONU: Progress, Challenges, and Solutions,” IEEE Network  March/April 2012 pp. 36-41.
[3] Jingjing Zhang and Nirwan Ansari “Toward Energy-Efficient 1G-EPON and 10G-EPON with Sleep-Aware MAC Control and Scheduling,” IEEE Communications Magazine February 2011 pp. s34-38.
Описание слайда:
Reference [1] Glen Kramer and Biswanath Mukherjee “IPACT: A Dynamic Protocol for an Ethernet PON (EPON),” IEEE Communications Magazine, February 2002. [2] Lei Shi, Biswanath Mukherjee and Sang-Soo Lee “Energy-Efficient PON with Sleep-Mode ONU: Progress, Challenges, and Solutions,” IEEE Network March/April 2012 pp. 36-41. [3] Jingjing Zhang and Nirwan Ansari “Toward Energy-Efficient 1G-EPON and 10G-EPON with Sleep-Aware MAC Control and Scheduling,” IEEE Communications Magazine February 2011 pp. s34-38.

Слайд 33





Thanks for your listening
Описание слайда:
Thanks for your listening